More about SunStar® Infrared Tube Heater - SIS Series - 75,000 BTU - 30' Tube
The perfect heater for hard-to-heat spaces like your warehouse or garage, the SunStar 75,000 BTU SIS Series Infrared Tube Heater with a 30' long tube provides both the fuel efficiency of radiant heat and the installation flexibility you need. This Tough Guy heater features an emitter tube perfect for high humidity/corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.
Features
- Pull Through System
- CSA design certified
- Available in natural gas & propane
- Sidewall or through the roof venting
- Vented or indirect vented operation
- Includes 36″ stainless steel gas connector
Vacuum System
- Products of combustion are pulled through the combustion chamber for increased radiant efficiency & greater safety
- No draft hoods, totally enclosed combustion chamber
- Heavy-duty draft inducer assembly with permanently lubricated, totally enclosed & heavy-duty ball bearing motor for maintenance-free operation
- 30-second per-purge period before ignition
- Diaphragm air switch for proof of venting before gas flow & ignition
Radiant Emitter Tube System
- 4” O.D. heat treated aluminized steel combustion chamber; 10’ length
- Standard highly emissive radiant tubes; 10’ length
- Aluminized steel radiant tubes
- 5-year limited manufacturer warranty on all tubes
- Suitable for horizontal or angle mounting up to 45°
- Up to 75 feet sidewall vent capability
Burner System
- Heavy-duty cast iron burner
- Reliable direct spark ignition system & 100% Gas Shut-Off Safety Control
- Burner inspection sight glass
- Step-opening redundant combination gas valve for quite ignition & added safety
- Inside or outside air for combustion
- Up to 50 ft. outside combustion air capability
- Diagnostic Monitoring Light System
Reflector System
- Highly efficient aluminum reflectors
- Individual reflectors can be rotated up to 45° to direct heat where needed
QC Part # | Vendor Part # | BTUs | Total Tube Length | Overall Length |
---|---|---|---|---|
22651 | SIS50-15-TG | 50,000 | 15' | 17'9" |
22652 | SIS50-20-TG | 50,000 | 20' | 22'9" |
22653 | SIS50-30-TG | 50,000 | 30' | 32'9" |
22654 | SIS75-20-TG | 75,000 | 20' | 22'9" |
22655 | SIS75-30-TG | 75,000 | 30' | 32'9" |
22656 | SIS100-30-TG | 100,000 | 30' | 32'9" |
22657 | SIS100-40-TG | 100,000 | 40' | 42'9" |
22658 | SIS125-30-TG | 125,000 | 30' | 32'9" |
22659 | SIS125-40-TG | 125,000 | 40' | 42'9" |
22660 | SIS125-50-TG | 125,000 | 50' | 52'9" |
22661 | SIS150-40-TG | 150,000 | 40' | 42'9" |
22662 | SIS150-50-TG | 150,000 | 50' | 52'9" |
22663 | SIS175-40-TG | 175,000 | 40' | 42'9" |
22664 | SIS175-50-TG | 175,000 | 50' | 52'9" |
Applications: Manufacturing Plants, Warehouses, Auto Dealerships, Aircraft Hangars, Loading Docks, Weld Shops, Fire Stations, Gymnasiums, Garages, Machine Shops, Tennis Courts, Maintenance Shops, Farm Buildings, Truck Service Areas, Auto Body Shops, and MORE!
Requirements
Gas Type | Burner Pressure | Supply Pressure | Voltage | Amps | Ignition Type | |
---|---|---|---|---|---|---|
Min | Max | |||||
Natural Gas | 3.5" W.C. | 5" W.C. | 14" W.C. | 120 VAC, 60 Hz | 2.4 | Direct Spark |
Liquid Propane | 10" W.C. | 11" W.C. | 14" W.C. | 120 VAC, 60 Hz | 2.4 | Direct Spark |
Minimum Mounting Heights
Model | Height @ Horizontal | Height @ 45° Angle | ||
---|---|---|---|---|
SIS 50 | 11' | 10' | ||
SIS 75 | 13' | 12' | ||
SIS 100 | 14' | 13' | ||
SIS 125 | 14' | 13' | ||
SIS 150 | 15' | 14' | ||
SIS 175 | 16' | 15' | ||
NOTES: Since straight tubes are always hotter at the burner end than at the exhaust end, always observe the minimum recommended mounting heights shown on the specification sheet for greatest human comfort. Use SIU series instead of SIS series for spot heating applications. |